Gas flowmeters Turbo Flow UFG-F

Purpose:

Ultrasonic gas flowmeters are intended for high-accuracy measurement (0.3%):

  • Volumetric gas flow rate;
  • Mass gas flow rate

in operating and standard conditions in pipelines DN 50…500 mm.

The electronic computing unit:

  • Takes measurement of gas flow parameters: temperature, pressure.
  • Makes computation of accumulated gas volume.
  • Archives measured parameters.
  • Optional: data transfer via mobile communication or Ethernet links.

For Class A meters – backing up of computer aids (Corporate Standard of Gazprom OJSC).

Field of application:

The Turbo Flow UFG-F gas flowmeters are used for commercial and technological metering of natural, oil and other kinds of gas at production facilities of various industries.

Advantages of method:

  • High accuracy of measurements: measurement error up to 0.3%;

  • Wide dynamic range: 1:200;

  • Flow measurement in both directions;

  • No pressure losses due to full bore diamete.

Our engineers together with the researchers from the South Federal University carried out a series of studies in the ultrasonic flow measurement field. The twoyear effort has resulted in a unique measuring system based on the special-purpose piezoelectric transducers that are not sensitive to contaminating deposits up to 1 mm thick. This offers the possibility to successfully use our flowmeters for metering

Configuration options:

Based on components and performed functions:

  • Configuration С0 – includes an ultrasonic flow transducer, an electronic unit;
  • Configuration С1Т – includes an ultrasonic flow transducer, electronic unit, temperature transducer, flow computer integrated in electronic unit;
  • Configuration С1ТР – includes an ultrasonic flow transducer, electronic unit, temperature transducer, flow computer integrated in electronic unit, pressure transducer;
  • Configuration  С2ТР – includes an ultrasonic flow transducer, electronic unit, temperature transducer, a flow computer remotely installed in a flow-measurement cabinet, pressure transducer;
  • Configuration С3ТР – includes an ultrasonic flow transducer, electronic unit, temperature transducer, pressure transducer, a Raskhod-1 flow computer.
  • Configuration С4 – includes an ultrasonic flow transducer, electronic unit, temperature transducer, pressure transducer, a Superflow-23 gas volume corrector.

Based on explosion protection:

  • 1 Ex dib [ia Ga] IIC T4 Gb;
  • 1 Ex d [ia Ga] IIC T4 Gb.

Based on redundant computer aids:

  • One computing unit;
  • Two computing units;
  • Two computing units, redundant flow parameter measuring equipment (“two-in-one” configuration).

Additional equipment:

Flow-measurement cabinet

Flow conditioner

Device to replace ultrasonic sensors RUS